HP MSA2324sa HP StorageWorks 2300 Family Modular Smart Array CLI reference gui - Page 129
show disk-parameters
View all HP MSA2324sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
show disk-parameters Description Shows disk settings. Syntax show disk-parameters Output SMART Shows whether SMART is enabled or disabled for all disks, or is set to detect-only, which specifies that each new disk inserted in the system retains its current SMART setting. Drive Write Back Cache Shows whether write-back cache for each disk in or added to the system will be enabled or disabled or a rescan or controller restart. Don't Modify means that each disk's current setting will not be modified. Timeout Retry Maximum Maximum number of times a timed-out I/O operation can be retried before the operation is failed. Attempt Timeout Number of seconds before an I/O operation is aborted and possibly retried. Overall Timeout Total time in seconds before an I/O operation is failed regardless of the Attempt Timeout and Number of Retries settings. Example Show disk settings: # show disk-parameters Disk Parameters SMART: Enabled Drive Write Back Cache: Disabled Timeout Retry Maximum: 3 Attempt Timeout: 8 Overall Timeout: 105 See also • set disk-parameters HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide 129