HP MSA2324sa HP StorageWorks 2300 Family Modular Smart Array CLI reference gui - Page 117
Temperature Exceeded, Partner Notify, Auto Write Back
![]() |
View all HP MSA2324sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
Temperature Exceeded Shows whether the system forces a controller shutdown when a temperature is detected that exceeds system threshold limits. Partner Notify Shows whether the partner controller is notified when a trigger condition occurs. Auto Write Back Shows whether the cache mode automatically changes to write-back after the trigger condition is cleared. Example Show advanced system-configuration settings: # show advanced-settings Background Scrub: enabled Partner Firmware Upgrade: disabled Utility Priority: High SMART: Enabled Dynamic Spare Configuration: Disabled Enclosure Polling Rate: 5 Host Control of Caching: enabled Sync Cache Mode: Immediate Missing LUN Response: Not Ready Controller Failure: Disabled SuperCap Failure: Enabled CompactFlash Failure: Enabled Power Supply Failure: Disabled Fan Failure: Disabled Temperature Exceeded: Disabled Partner Notify: Disabled Auto Write Back: Enabled See also • set advanced-settings HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide 117
![](/manual_guide/products/hewlettpackard-msa2312i-hp-storageworks-2300-family-modular-smart-array-cli-reference-guide-500912002-2010-2bf014b/117.png)