HP MSA2324sa HP StorageWorks 2300 Family Modular Smart Array CLI reference gui - Page 81

SCSI SYNCHRONIZE CACHE, sync-cache-mode immediate|flush

Page 81 highlights

partner-firmware-upgrade enabled|disabled|on|off Optional. Sets whether component firmware versions are monitored and will be automatically upgraded on the partner controller. partner-notify enabled|disabled|on|off Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this option to have the partner also change to write-through mode for better data protection. Disable this option to allow the partner continue using its current caching mode for better performance. The default is disabled. power-supply-failure enabled|disabled|on|off Optional. Sets whether the cache policy automatically changes to write-through when a power supply fails. smart enabled|disabled|on|off Optional. Enables or disables Self-Monitoring Analysis and Reporting Technology in disk drives. super-cap-failure enabled|disabled|on|off Optional. Sets whether the cache policy automatically changes to write-through when cache backup power is not fully charged or fails. sync-cache-mode immediate|flush Optional. Sets the option that controls how the SCSI SYNCHRONIZE CACHE command is handled. • immediate: Good status is returned immediately and cache content is unchanged. This option is the default. • flush: Good status is returned only after all write-back data for the specified volume is flushed to disk. temperature-exceeded enabled|disabled|on|off Optional. Sets whether the system forces a controller shutdown if a temperature is detected that exceeds system threshold limits. utility-priority low|medium|high Optional. Sets the priority at which jobs (such as vdisk verification and reconstruction but not background scrub) run with respect to I/O operations competing for the system's processors: low, medium, or high. Example Enable partner firmware upgrade: # set advanced-settings partner-firmware-upgrade enabled Info: Command completed successfully. - Parameter 'partner-firmware-upgrade' was set to 'enabled'. Success: Command completed successfully. - The settings were changed successfully. See also • show advanced-settings HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide 81

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide
81
partner-firmware-upgrade enabled|disabled|on|off
Optional. Sets whether component firmware versions are monitored and will be automatically
upgraded on the partner controller.
partner-notify enabled|disabled|on|off
Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this
option to have the partner also change to write-through mode for better data protection. Disable this
option to allow the partner continue using its current caching mode for better performance. The
default is
disabled
.
power-supply-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a power
supply fails.
smart enabled|disabled|on|off
Optional. Enables or disables Self-Monitoring Analysis and Reporting Technology in disk drives.
super-cap-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when cache backup
power is not fully charged or fails.
sync-cache-mode immediate|flush
Optional. Sets the option that controls how the
SCSI SYNCHRONIZE CACHE
command is handled.
immediate
: Good status is returned immediately and cache content is unchanged. This option
is the default.
flush
: Good status is returned only after all write-back data for the specified volume is flushed
to disk.
temperature-exceeded enabled|disabled|on|off
Optional. Sets whether the system forces a controller shutdown if a temperature is detected that
exceeds system threshold limits.
utility-priority low|medium|high
Optional. Sets the priority at which jobs (such as vdisk verification and reconstruction but not
background scrub) run with respect to I/O operations competing for the system's processors: low,
medium, or high.
Example
Enable partner firmware upgrade:
# set advanced-settings partner-firmware-upgrade enabled
Info: Command completed successfully. - Parameter 'partner-firmware-upgrade' was
set to 'enabled'.
Success: Command completed successfully. - The settings were changed
successfully.
See also
show advanced-settings