HP MSA2324sa HP StorageWorks 2300 Family Modular Smart Array CLI reference gui - Page 134

Show enclosure status for a system with a controller enclosure and an MSA70 drive enclosure

Page 134 highlights

Add'l Data Additional data such as fan speed (RPM), temperature (Celsius), voltage, or slot address Example Show enclosure status for a system with a controller enclosure and an MSA70 drive enclosure: # show enclosure-status Chassis Vendor Product ID CPLD EMP A BUS:ID Rev EMP B BUS:ID Rev WWPN Status Health 3CL816C013 vendor product 8 0:31 1022 1:31 1022 500C0FF00000133C OK OK Type # Status FRU P/N FRU S/N Add'l Data FAN 01 OK PN SN speed=5980 FAN 02 OK PN SN speed=6070 PSU 01 OK PN SN -- PSU 02 OK PN SN -- Temp 01 OK PN SN temp=37 ... Temp 04 OK PN SN temp=33 Voltage 01 OK PN SN voltage=11.86V ... Voltage 10 OK PN SN voltage=3.49V Disk 01 OK PN SN addr=0 Disk 02 OK PN SN addr=1 ... Chassis Vendor Product ID CPLD EMP A BUS:ID Rev EMP B BUS:ID Rev WWPN Status Health N/A HP MSA70 N/A 1:63 2.18 0:63 2.18 50014380004C3F80 OK OK Type # Status FRU P/N FRU S/N Add'l Data FAN 01 OK N/A N/A speed=5400 ... FAN 04 OK N/A N/A speed=5400 PSU 01 OK N/A N/A -- PSU 02 OK N/A N/A -- Temp 01 OK N/A N/A temp=37 ... Temp 04 OK N/A N/A temp=35 Disk 01 OK N/A SN -- ... Disk 25 OK N/A SN -- See also • show enclosures 134

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

134
Add'l Data
Additional data such as fan speed (RPM), temperature (Celsius), voltage, or slot address
Example
Show enclosure status for a system with a controller enclosure and an MSA70 drive enclosure:
# show enclosure-status
Chassis
Vendor
Product ID
CPLD
EMP A BUS:ID Rev
EMP B BUS:ID Rev
WWPN
Status
Health
--------------------------------------------------------------------------
3CL816C013
vendor
product
8
0:31 1022
1:31 1022
500C0FF00000133C
OK
OK
--------------------------------------------------------------------------
Type
#
Status
FRU P/N
FRU S/N
Add'l Data
--------------------------------------------------------------------------
FAN
01 OK
PN
SN
speed=5980
FAN
02 OK
PN
SN
speed=6070
PSU
01 OK
PN
SN
--
PSU
02 OK
PN
SN
--
Temp
01 OK
PN
SN
temp=37
...
Temp
04 OK
PN
SN
temp=33
Voltage
01 OK
PN
SN
voltage=11.86V
...
Voltage
10 OK
PN
SN
voltage=3.49V
Disk
01 OK
PN
SN
addr=0
Disk
02 OK
PN
SN
addr=1
...
--------------------------------------------------------------------------
Chassis
Vendor
Product ID
CPLD
EMP A BUS:ID Rev
EMP B BUS:ID Rev
WWPN
Status
Health
--------------------------------------------------------------------------
N/A
HP
MSA70
N/A
1:63 2.18
0:63 2.18
50014380004C3F80
OK
OK
--------------------------------------------------------------------------
Type
#
Status
FRU P/N
FRU S/N
Add'l Data
--------------------------------------------------------------------------
FAN
01 OK
N/A
N/A
speed=5400
...
FAN
04 OK
N/A
N/A
speed=5400
PSU
01 OK
N/A
N/A
--
PSU
02 OK
N/A
N/A
--
Temp
01 OK
N/A
N/A
temp=37
...
Temp
04 OK
N/A
N/A
temp=35
Disk
01 OK
N/A
SN
--
...
Disk
25 OK
N/A
SN
--
--------------------------------------------------------------------------
See also
show enclosures