Page 269 highlights
Rev 1.6.9 stats alarm rate-limit stats alarm rate-limit {count | reset | window } Configures alarms rate limit. Syntax Description alarm ID Alarms supported by the system, for example: • cpu_util_indiv - Average CPU utilization too high: per- cent utilization • disk_io - Operating System Disk I/O per second too high: kilobytes per second • fs_mnt - Free filesystem space too low: percent of disk space free • intf_util - Network utilization too high: bytes per second • memory_pct_used - Too much memory in use: percent of physical memory used • paging - Paging activity too high: page faults • temperature - Temperature is too high: degrees count-type Long medium, or short count (number of alarms). reset Set the count and window durations to default values for this alarm. window-type Long medium, or short count, in seconds. Default Short window: 5 alarms in 1 hour Medium window: 20 alarms in 1 day Long window: 50 alarms in 7 days Configuration Mode Config History 3.1.0000 Role monitor/admin Example switch (config) # stats alarm paging rate-limit window long 2000 switch (config) # Related Commands show stats alarm Note Mellanox Technologies 269 Mellanox® Technologies Confidential