HP StorageWorks 2/140 director product manager user guide - Page 148
Hardware Log, FRU Position, BKPLNE, Event Data
![]() |
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 148 highlights
Using Logs - 0=Informational - 2=Minor - 3=Major - 4=Severe (not operational) • FRU Position-An acronym representing the FRU type, followed by a number representing the FRU chassis position. FRU acronyms are: - BKPLNE-backplane. - CTP-control processor (CTP) card. - SBAR-serial crossbar (SBAR) card. - Port-card. - FAN-fan module. - PWR-power supply. The chassis (slot) position for a nonredundant FRU is 0. The chassis positions for redundant FRUs are 0, 1, and 2. The chassis positions for port cards are 0 through 35, and slot 32 is unavailable. • Event Data-Up to 32 bytes of supplementary information for the event in hexadecimal format. For detailed information on event data and problem resolution, refer to the event code tables appendix in the hp StorageWorks director 2/64 service manual for the Director 2/64 and the hp StorageWorks director 2/140 service manual for the Director 2/140. Hardware Log The Hardware Log displays information on FRUs inserted and removed from the director. 4-6 director product manager user guide
![](/manual_guide/products/hewlettpackard-storageworks-2140-director-product-manager-user-guide-466694f/148.png)