Information and Error Messages Table A-1: Product Manager Messages (Continued) Message Cannot run diagnostics on a port that is not installed. Cannot run diagnostics on a port card that is not installed. Cannot run diagnostics while a device is logged-in to the port. Cannot save IPL configuration while active=saved is enabled. Cannot save port configuration. Cannot save SNMP configuration. Description Port diagnostics cannot be performed on a port card that is not installed. Port diagnostics (loopback tests) cannot be performed on a port that does not have a small form factor (SFF) optical transceiver installed. Port diagnostics (internal loopback test) cannot be performed on a port while an attached Fibre Channel device is logged in. The user cannot save the IPL file while the active=saved property is set. The port configuration cannot be saved at the Product Manager application because the Ethernet link is down or busy. The director SNMP configuration cannot be saved at the Product Manager application because the Ethernet link is down or busy. Action Run diagnostics only on a port that is installed. Install a transceiver in the port and perform diagnostics again. Ensure the device is logged out and perform diagnostics again. The FICON management server property, active=save, must be disabled for HAFM to save the IPL file. Retry the operation later. If the condition persists, contact the next level of support. Retry the operation later. If the condition persists, contact the next level of support. director product manager user guide A-7