HP StorageWorks 2/140 director product manager user guide - Page 43
Table 1-1, Operating Status-Status Bar and Director Status, Symbol, Alert Panel, Director Status
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Product Manager Overview Table 1-1: Operating Status-Status Bar and Director Status Symbol Alert Panel Green Circle Director Status Table Text Fully Operational Meaning All components and installed ports are operational; no failures. Yellow Triangle Redundant Failure Minor Failure Blinking Red Diamond with Yellow Background Not Operational A redundant component has failed, such as a power supply, and the backup component has taken over operation. A failure occurred which has decreased the director operational ability. Normal switching operations are not affected. • One or more port cards failed, but at least one port card is still operational. • A fan has failed or is not rotating sufficiently. • One of two CTP cards failed. • One of two SBAR cards failed. A critical failure prevents the director from performing fundamental switching operations. • All fans fail. • Both SBAR cards fail. • All installed port cards fail. director product manager user guide 1-25