HP StorageWorks 2/140 director product manager user guide - Page 79

Con Ports, Bound WWN, Configuring Fabric Operating, Parameters, Configuring, Ports

Page 79 highlights

Monitoring and Managing the Director - Incompatible operating parameters. Operating parameters, such as resource allocation time-out values (R_A_TOV) or error-detect time-out values (E_D_TOV), are inconsistent. Refer to "Configuring Fabric Operating Parameters" on page 3-6 for more information. - Duplicate domain IDs. Identical preferred domain IDs are configured for two or more directors or switches. Refer to "Configuring Switch Operating Parameters" on page 3-2 for more information. - Incompatible zoning configurations. Refer to the hp StorageWorks ha-fabric manager user guide and the hp StorageWorks director 2/64 service manual for more information on zoning. - Build fabric protocol error. - No principal switch. A principle director or switch is not defined for the fabric. - No response from the attached switch. - ELP retransmission failure timeout. A director or switch with a hardware or link failure attempted to join the fabric and transmitted multiple exchange link protocol (ELP) frames to another director or switch. Because of the failure, the failed director or switch did not receive responses to the ELP frames and did not receive a FLOGI frame. The failed director or switch times out. A port binding error may be due to an invalid WWN or nickname entry in the Configure Ports dialog box in the Bound WWN column. Refer to "Configuring Ports" on page 3-9 for a description of the Configure Ports dialog box. Reasons messages for an invalid attachment can include: - 01 Unknown. The reason is not known. - 02 ISL connection not allowed on this port. ISL is connected to a port configured as an F_Port. - 03 ELP rejected by the attached switch. This director or switch transmitted an exchange link protocol (ELP) frame that was rejected by the switch at the other end of the ISL. - 04 Incompatible switch at other end of the ISL. The switch is configured for Open Fabric mode, and the switch at the other end of the ISL is an HP switch configured for Homogeneous mode. - 05 External loopback adapter connected to the port. A loopback plug is connected to the port, and no diagnostic test running. director product manager user guide 2-19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244

director product manager user guide
2–19
Monitoring and Managing the Director
Incompatible operating parameters.
Operating parameters, such as resource
allocation time-out values (R_A_TOV) or error-detect time-out values
(E_D_TOV), are inconsistent. Refer to “
Configuring Fabric Operating
Parameters
” on
page 3–6
for more information.
Duplicate domain IDs. Identical preferred domain IDs are configured for two
or more directors or switches. Refer to “
Configuring Switch Operating
Parameters
” on
page 3–2
for more information.
Incompatible zoning configurations. Refer to the
hp StorageWorks ha-fabric
manager user guide
and the
hp StorageWorks director 2/64 service manual
for
more information on zoning.
Build fabric protocol error.
No principal switch. A principle director or switch is not defined for the
fabric.
No response from the attached switch.
ELP retransmission failure timeout. A director or switch with a hardware or
link failure attempted to join the fabric and transmitted multiple exchange link
protocol (ELP) frames to another director or switch. Because of the failure,
the failed director or switch did not receive responses to the ELP frames and
did not receive a FLOGI frame. The failed director or switch times out.
A port binding error may be due to an invalid WWN or nickname entry in the
Configure Ports
dialog box in the
Bound WWN
column. Refer to “
Configuring
Ports
” on
page 3–9
for a description of the
Configure Ports
dialog box.
Reasons messages for an invalid attachment can include:
01 Unknown
. The reason is not known.
02 ISL connection not allowed on this port
. ISL is
connected to a port configured as an F_Port.
03 ELP rejected by the attached switch
. This director or
switch transmitted an exchange link protocol (ELP) frame that was rejected
by the switch at the other end of the ISL.
04 Incompatible switch at other end of the ISL.
The
switch is configured for Open Fabric mode, and the switch at the other end of
the ISL is an HP switch configured for Homogeneous mode.
05 External loopback adapter connected to the port
. A
loopback plug is connected to the port, and no diagnostic test running.