HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 183
Disabling Partner Firmware Upgrade, Changing Utility Priority
![]() |
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 183 highlights
Disabling Partner Firmware Upgrade If a service technician tells you to disable partner firmware upgrade: 1. Select Manage > General Config > System Configuration. 2. Set Partner Firmware Upgrade to Disabled. Changing Utility Priority You can change the priority at which the Verify, Reconstruct, Expand, and Initialize utilities run when there are active I/O operations competing for the system's controllers. Priority Value Description High Use when your highest priority is to get the system back to a fully fault-tolerant state. This causes heavy I/O with the host to be slower than normal. This value is the default. Medium Use when you want to balance data streaming with data redundancy. Low Use when streaming data without interruption, such as for a web server, is more important than data redundancy. This enables the Reconstruct or other utility to run at a slower rate with minimal effect on host I/O. To change utility priority: 1. Select Manage > General Config > System Configuration. 2. For Utility Priority, select a priority. 3. Click Change System Configuration. Chapter 6 Additional Configuration Functions and Utilities 183
![](/manual_guide/products/hewlettpackard-2000fc-hp-storageworks-2000-modular-smart-array-reference-guide-481599003-2008-ec3ca96/183.png)