HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 283
interface command to shut down or, restart the controller.
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 283 highlights
TABLE E-1 Event Descriptions and Recommended Actions (Continued) Event Code 90 95 96 100 101 103 104 105 106 Event Type Description Recommended Action Informational The partner controller does not have a mirrored configuration image for the current controller, so the current controller's local flash configuration is being used. This event is expected if the other controller is new or its configuration has been cleared. Critical Both controllers in an active-active configuration have the same serial number. Non-unique serial numbers can cause system problems; for example, vdisk ownership and WWNs are determined by serial number. A service technician must examine both controller serial numbers and change at least one of them. Informational Pending configuration changes that take effect at startup were ignored because customer data might be present in cache. If the requested configuration changes did not occur, make the changes again and then use a userinterface command to shut down or restart the controller. Informational During active-active operation, an event (potential error) occurred while communicating with the EMP, which reports SES data. Informational An update of EMP data has been triggered. This event is for internal use only. Informational Volume name change is complete. Informational Volume size change is complete. Informational Volume LUN change is complete. Informational A volume has been added. Appendix E Event Codes 283