HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 283

interface command to shut down or, restart the controller.

Page 283 highlights

TABLE E-1 Event Descriptions and Recommended Actions (Continued) Event Code 90 95 96 100 101 103 104 105 106 Event Type Description Recommended Action Informational The partner controller does not have a mirrored configuration image for the current controller, so the current controller's local flash configuration is being used. This event is expected if the other controller is new or its configuration has been cleared. Critical Both controllers in an active-active configuration have the same serial number. Non-unique serial numbers can cause system problems; for example, vdisk ownership and WWNs are determined by serial number. A service technician must examine both controller serial numbers and change at least one of them. Informational Pending configuration changes that take effect at startup were ignored because customer data might be present in cache. If the requested configuration changes did not occur, make the changes again and then use a userinterface command to shut down or restart the controller. Informational During active-active operation, an event (potential error) occurred while communicating with the EMP, which reports SES data. Informational An update of EMP data has been triggered. This event is for internal use only. Informational Volume name change is complete. Informational Volume size change is complete. Informational Volume LUN change is complete. Informational A volume has been added. Appendix E Event Codes 283

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330

Appendix E
Event Codes
283
90
Informational
The partner controller does not have a
mirrored configuration image for the
current controller, so the current
controller’s local flash configuration
is being used. This event is expected
if the other controller is new or its
configuration has been cleared.
95
Critical
Both controllers in an active-active
configuration have the same serial
number. Non-unique serial numbers
can cause system problems; for
example, vdisk ownership and
WWNs are determined by serial
number.
A service technician must examine
both controller serial numbers and
change at least one of them.
96
Informational
Pending configuration changes that
take effect at startup were ignored
because customer data might be
present in cache.
If the requested configuration
changes did not occur, make the
changes again and then use a user-
interface command to shut down or
restart the controller.
100
Informational
During active-active operation, an
event (potential error) occurred while
communicating with the EMP, which
reports SES data.
101
Informational
An update of EMP data has been
triggered. This event is for internal
use only.
103
Informational
Volume name change is complete.
104
Informational
Volume size change is complete.
105
Informational
Volume LUN change is complete.
106
Informational
A volume has been added.
TABLE E-1
Event Descriptions and Recommended Actions
(Continued)
Event
Code
Event Type
Description
Recommended Action