Page 297 highlights
TABLE E-1 Event Descriptions and Recommended Actions (Continued) Event Code 265 266 268 269 270 271 272 273 274 275 Event Type Description Recommended Action Informational Port bypass circuits currently use the service port, which may limit the link speed or interconnect mode support. Perform a system-level shutdown and restart. Note that this will cause all data to be unavailable for about 1 minute. Informational A copy operation for the specified master volume has been aborted. Informational A background copy operation for the specified master volume completed. Informational A partner firmware update operation has started. This operation is used to copy firmware from one controller to the other to bring both controllers up to the same version of firmware. Warning There is a problem reading or writing the persistent IP data from the FRUID SEEPROM, or if invalid data is read from the FRU-ID SEEPROM. Check the IP settings (including iSCSI host channel IP data for an iSCSI system), and update them if they are incorrect. Informational System could not get a valid serial number from the controller's FRU-ID SEEPROM, either because it couldn't read the FRU-ID data, or because the data on it isn't valid or hasn't been programmed. Therefore, the MAC address is derived by using the controller's serial number from flash. This event is only logged one time during bootup. Informational The snap pool is being expanded. Informational Fault isolation has been enabled or disabled for the specified enclosure and controller within that enclosure. Informational A phy has been disabled. Informational A phy has been enabled. Appendix E Event Codes 297