HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 280
Event, Event Type, Description, Recommended Action, data have been inserted from another
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 280 highlights
TABLE E-1 Event Descriptions and Recommended Actions (Continued) Event Code 60 61 62 65 67 68 69 71 72 Event Type Description Recommended Action Informational A disk channel was reset from another initiator or target. Critical A serious error, which might indicate hardware failure, occurred while communicating on the specified disk channel. The controller will attempt to recover. • If the controller recovers, no action is required. • View other logged events to determine other action to take. Informational A spare drive has failed. Replace the failed drive. Critical An uncorrectable ECC error occurred on the buffer memory on startup. The controller is automatically restarted and-if it was operating in activeactive mode (i.e., independent cache performance mode was disabled)-its cache data is restored from the partner controller's cache. Informational The controller has identified a new disk drive or group of disk drives that constitute a vdisk and has taken ownership of the vdisk. This can happen when disk drives containing data have been inserted from another enclosure. Informational Controller is in a shut-down state. Critical Enclosure reported a general failure. Check the controller module or expansion module for problems such as not being fully inserted, and for bad cables. Informational The controller has started or completed failing over. Informational (Active-active environment) After failover, recovery has started or has completed. 280 HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008