HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 299
memory. This flag is set during, startup, and if set, this event is logged
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 299 highlights
TABLE E-1 Event Descriptions and Recommended Actions (Continued) Event Code 307 308 309 310 313 Event Type Description Recommended Action Critical A temperature sensor on a controller FRU detected an over-temperature condition that caused the controller to shut down. • Check that the storage system's fans are running. • Check that the ambient temperature is not too warm. The enclosure operating range is 41° F to 104° F (5° C to 40° C). • Check for any obstructions to the airflow. • If none of the above explanations apply, replace the controller FRU that reported the error. Informational The default host port speed has changed from 4 Gbit/sec to 2 Gbit/sec because the controller module's HIM has a Broadcom PBC. Informational Normally when the Management Controller is started, the IP data is obtained from the SEEPROM where it is persisted. If the system is unable to write it to the SEEPROM the last time it changed, a flag is set in flash memory. This flag is set during startup, and if set, this event is logged and the IP data that is in flash memory is used. The only time that this would not be the correct IP data would be if the controller board was swapped and then whatever data is on the board's flash memory is used. Informational After a rescan, the controller completed back-end discovery and initialization of enclosure data. Critical An I/O module is down and will not be automatically restarted. This only applies when the other SC goes down. The SC needs service or replacement. Appendix E Event Codes 299