HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 296
created and committed., can be used.
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 296 highlights
TABLE E-1 Event Descriptions and Recommended Actions (Continued) Event Code 249 250 252 256 257 258 259 260 261 262 263 264 Event Type Description Recommended Action Informational A valid license has been installed for the specified feature. This event is logged for each feature license installed. Warning A license could not be installed (license is invalid). Check license parameters against what is allowed for the platform and recreate the license using valid parameters, then reinstall. Review the readme file that came with the license. Informational Snapshot write data on the specified master volume has been deleted. Informational The specified snapshot has been created but not committed. A commit action is required before the snapshot can be used. Informational The specified snapshot has been created and committed. Informational The specified snapshot has been committed and is ready for use. Informational Inband CAPI commands have been disabled. Informational Inband CAPI commands have been enabled. Informational Inband SES commands have been disabled. Informational Inband SES commands have been enabled. Warning The specified drive spare is missing. It was either removed or is not responding. Replace the specified drive. Informational The link speed of the port bypass circuit and interconnect mode has been set to the default. 296 HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008