HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 275
E, Event Codes
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 275 highlights
APPENDIX E Event Codes Information in this appendix is for reference by storage administrators and technical support personnel to aid troubleshooting. Event messages appear in the event log, which you can view using SMU or the CLI, and in debug logs. You may also receive notifications, depending on your SMU event notification settings. The following table describes the events that can occur during operation. Events are listed in order by numeric event code. Recommended actions available at this time are also listed. TABLE E-1 Event Descriptions and Recommended Actions Event Code 1 3 Event Type Warning Critical Description Recommended Action A disk drive in the specified vdisk failed. The vdisk is online but not fault tolerant. If a spare is present the controller automatically uses the spare to reconstruct the vdisk. • See "Disk Drive Errors and Recommended Actions" on page 300. • If dynamic spares is enabled, replace the failed drive. The system automatically reconstructs the vdisk. • If dynamic spares is disabled and no spare is available, replace the failed drive and add it as a vdisk spare to the critical vdisk. The specified vdisk is now offline. If a spare is present the controller automatically uses the spare to reconstruct the vdisk. If no spare is available, replace the failed drive and add it as a vdisk spare to the critical vdisk. 4 Informational A drive had an uncorrectable error and the controller reassigned the block. 275