HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 291
The Serial Attached SCSI SAS, expected disks are detected. If
![]() |
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 291 highlights
TABLE E-1 Event Descriptions and Recommended Actions (Continued) Event Code 207 208 209 210 211 212 213 214 Event Type Description Recommended Action Informational Vdisk scrub has completed. The event message reports the number of: • Data parity mismatches for RAID 3, 5, 6, and 50 • Mirror verify errors for RAID 1 and 10 • Medium errors for other types Informational Drive scrub has started. Informational Drive scrub has completed. Informational All snapshot volumes have been deleted. Informational or Warning The Serial Attached SCSI (SAS) topology has changed; components were added or removed. The message specifies the number of elements in the SAS map, the number of expanders detected, the number of expansion levels on the native (local controller) side and on the partner (partner controller) side, and the number of device PHYs. This event is logged as informational anytime the number of SAS expanders change. This event is logged as a warning if no elements are detected in the SAS map. If the event is a warning, ensure that the SAS map is up and that all expected disks are detected. If the SAS map is not up or expected disks are not detected, perform a rescan. If a rescan does not resolve the problem, then shut down and restart both controllers. Informational All master volumes have been deleted. Informational A standard volume has been converted to a master volume or a master volume has been converted to a standard volume. Informational The creation of snapshots is complete. The number of snapshots is specified. Appendix E Event Codes 291
![](/manual_guide/products/hewlettpackard-2000fc-hp-storageworks-2000-modular-smart-array-reference-guide-481599003-2008-ec3ca96/291.png)