HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 219
Event Severities, Viewing the Event Log
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 219 highlights
Event Severities The storage system generates events having three severity levels: ■ Informational - A problem occurred that the system corrected, or a system change has been made. These events are purely informational; no action required. ■ Warning - Something related to the system or to a virtual disk has a problem. Correct the problem as soon as possible. ■ Critical - Something related to the system or to a virtual disk has failed and requires immediate attention. There are a number of conditions that trigger warning or critical events and can affect the state of status LEDs. Viewing the Event Log Some of the key warning and error events included in the event log during operation include the following: ■ Disk detected error ■ Disk channel error ■ Drive down ■ Virtual disk critical ■ Virtual disk offline ■ Temperature warning ■ Temperature failure (this leads to a shutdown which is also logged) ■ Voltage warning ■ Voltage failure (this leads to a shutdown which is also logged) The event log stores the most recent events with a time stamp next to them with one-second granularity. Note - If you are having a problem with the system or a virtual disk, check the event log before calling technical support. Event messages might enable you to resolve the problem. You can save the event log to a file; see "Saving Log Information to a File" on page 192. Chapter 7 Troubleshooting Using SMU 219