HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 286
The host Fibre Channel World Wide, The Management Controller has been
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 286 highlights
TABLE E-1 Event Descriptions and Recommended Actions (Continued) Event Code 154 155 156 157 160 161 162 Event Type Description Recommended Action Informational New software has been loaded on the Management Controller. Informational New loader software has been loaded on the Management Controller. Informational The Management Controller has been restarted from the Storage Controller. Critical A failure occurred when trying to write to the Storage Controller flash chip. Replace the controller module. Warning The EMP enclosures are not configured correctly. All enclosure EMPs on that channel are disabled. Check that EMP enclosures are configured correctly and issue a rescan. Informational One or more enclosures do not have a valid path to an EMP. All enclosure EMPs are disabled. Warning The host Fibre Channel World Wide Names (node and port) previously presented by this controller module in this system are unknown. This event has two possible causes: • One or both controller modules have been replaced or moved while the system was powered off. • One or both controller modules have had their flash configuration cleared (this is where the previously used WWNs are stored). The controller module recovers from this situation by generating a WWN based on its own serial number. Verify the WWN information for this controller module on all hosts that access it. 286 HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008