HP StorageWorks MSA2012i HP StorageWorks 2000 Modular Smart Array Reference Gu - Page 290
logged. See events 190-200., Manually enable write-back cache.
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 290 highlights
TABLE E-1 Event Descriptions and Recommended Actions (Continued) Event Code Event Type Description Recommended Action 189 Informational A disk channel that was previously degraded or failed is now healthy. 190-201 Informational Includes component-specific environmental indicator events generated by the auto-write-through feature when an environmental change occurs. If an auto-writethrough-trigger condition has been met, write-back cache is disabled and event 188 is also logged. Once the fault is resolved, event 187 is logged to indicate that write-back mode has been restored. 202 Informational An auto-write-through-trigger condition has been cleared, causing write-back cache to be re-enabled. The environmental change is also logged. (See events 190-200 and 241 and 242.) 203 Warning An environmental change occurred Manually enable write-back cache. that allows write-back cache to be enabled, but the auto-write-back preference is not set. The environmental change is also logged. (See events 190-200.) 204 Warning or This event is generated by the Send the log file to the service informational hardware flush firmware whenever technician for further diagnosis. the boot processing firmware needs to inform the user about something. 205 Informational The specified volume has been mapped or unmapped. 206 Informational Vdisk scrub has started. 290 HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008