Disk Drive Errors and Recommended Actions, TABLE E-2
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 300 highlights
TABLE E-1 Event Descriptions and Recommended Actions (Continued) Event Code 314 Event Type Critical Description Recommended Action A FRU has failed or is not operating correctly. This event follows some other FRU specific event indicating a problem. Examine the FRU specified in the message to determine whether it needs to be replaced. Disk Drive Errors and Recommended Actions As referred to in TABLE E-1, the following table lists disk-drive error conditions and recommended actions. TABLE E-2 Disk Drive Error Conditions and Recommended Actions Status Recommended Action The status of the virtual disk that originally had the failed drive status is Good. A global or virtual disk (dedicated) spare has been successfully integrated into the virtual disk and the replacement drive module can be assigned as either a global spare or a virtual disk spare. Use SMU to assign the new drive module as either a global spare or a vdisk spare: Select Manage > Virtual Disk Config > Global Spare Menu. The status of the disk drive just installed is LEFTOVER. All of the member disk drives in a virtual disk contain metadata in the first sectors. The storage system uses the metadata to identify virtual disk members after restarting or replacing enclosures. Use SMU to clear the metadata if you have a disk drive that was previously a member of a virtual disk. After you clear the metadata, you can use the disk drive in a virtual disk or as a spare: Select Manage > Utilities > Disk Drive Utilities > Clear Metadata. Select the disk, and click on Clear Metadata for Selected Disk Drives. 300 HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008