RAID 3, which is calculated block-by-block for all user data. The parity information is
View all HP StorageWorks MSA2012i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 250 highlights
A mirrored virtual disk is also highly reliable, because both disk drives in a pair must fail for the virtual disk to fail. In an virtual disk with five pairs of mirrored disk drives, for example, the virtual disk can maintain its integrity even if five disks fail-as long as each pair is left with one good disk. The main disadvantage of a mirrored virtual disk is its cost. Because all disk drives must have a twin, you must use twice the number of disk drives that actually contribute to the virtual disk capacity. In an eight-disk virtual disk, for example, you have only four disks of usable capacity. RAID 3 RAID 3 virtual disks contain redundant information in the form of parity data, which is calculated block-by-block for all user data. The user data is distributed across all but one of the disk drives in the virtual disk. The parity data is written exclusively to the parity disk (also known as the check disk). In the event of a disk drive failure, the data can be reconstructed from corresponding data stripes on the remaining disk drives in the virtual disk. RAID 3 provides excellent I/O performance for applications that require high data transfer rates such as image processing, video processing, scientific data collection, batch data processing, or sequential reads and writes. RAID 3 is not well suited for transaction processing or other applications that require simultaneous reads and writes. RAID 5 RAID 5 virtual disks contain redundant information in the form of parity data, which is calculated block-by-block for all user data. The parity information is distributed across the disk drives in the virtual disk and occupies the equivalent capacity of approximately one disk drive. Data is interspersed with the parity information. If one disk drive in the virtual disk fails, the data on the failed disk drive can be reconstructed from the parity data and user data on the remaining disk drives. Two disk drives must fail before the entire virtual disk fails. The read performance of a RAID 5 virtual disk is excellent-comparable to that of a RAID 0 virtual disk. Write performance is lower than that of a RAID 0 virtual disk, because write operations involve calculating and writing new parity data as well as writing the new user data. 250 HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008