Determining the Faulty SIMM Pair
View all HP Visualize b180L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
Table 10 Troubleshooting Dealing with HPMC (Uncorrectable Error) Determining the Faulty SIMM Pair The address given by the System Responder Address is contiguous, even though empty slots are permitted. Memory boards are installed in pairs of the same memory capacity. The operating system starts mapping memory at Pair 3, if it exists. In other words, it maps starting with the highest numbered pair through to the Pair 0. To determine the faulty pair of SIMMs, perform the following steps. 1 Using Table 10, determine the HEX value address range for each SIMM pair in the system. Memory Address Ranges Pair Memory (3 thru 0) Size (MB) Address Range 0-8 8-16 16-24 24-32 32-40 40-48 48-56 56-64 64-72 72-80 80-88 88-96 96-104 0x00000000 - 0x007FFFFF 0x00800000 - 0x00FFFFFF 0x01000000 - 0x017FFFFF 0x01800000 - 0x01FFFFFF 0x02000000 - 0x027FFFFF 0x02800000 - 0x02FFFFFF 0x03000000 - 0x037FFFFF 0x38000000 - 0x03FFFFFF 0x04000000 - 0x047FFFFF 0,048000000 - 0x04FFFFF 0x05000000 - 0x057FFFFF 0x05800000 - 0x05FFFFFF 0x06000000 - 0x067FFFFF 85