Notes, Connect the other end of the SCSI cable to the Active PCI backplane or to a SCSI

Page 158 highlights

Notes: a. See "Features and connector locations of ServeRAID-4H controller" on page 139 for the channel connector locations of the 4H controller, "Features and connector locations of ServeRAID-4L controller" on page 141 for the channel connector locations of the 4L controller, and "Features and connector locations of ServeRAID-4M controller" on page 143 for the channel connector locations of the 4M controller. b. The following illustration depicts the ServeRAID-4H controller. The ServeRAID-4L controller will have a slightly different appearance. Figure 5. Connecting a ServeRAID-4H controller internal channel connector 11. Connect the other end of the SCSI cable to the Active PCI backplane or to a SCSI device in the server. (See your server documentation or the system label inside the server cover for the location of the SCSI connector on the backplane.) 12. If you have physical drives to install, install them now. See your server documentation for drive installation instructions. Note: The ServeRAID controllers use SCSI ID 7 and/or 6. 13. Install the server cover. 14. If you disconnected the cables and power cords in step 2 on page 146, reconnect the cables and cords. See your server documentation if you need detailed instructions. 148 Hardware Maintenance Manual: Netfinity 7600 - Type 8665 Models 1RY, 2RY

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294

148
Hardware Maintenance Manual: Netfinity 7600
Type 8665 Models 1RY, 2RY
Notes:
a.
See
Features and connector locations of ServeRAID-4H controller
on page
139 for the channel connector locations of the 4H controller,
Features and
connector locations of ServeRAID-4L controller
on page 141 for the channel
connector locations of the 4L controller, and
Features and connector
locations of ServeRAID-4M controller
on page 143 for the channel connector
locations of the 4M controller.
b.
The following illustration depicts the ServeRAID-4H controller.
The
ServeRAID-4L controller will have a slightly different appearance.
11.
Connect the other end of the SCSI cable to the Active PCI backplane or to a SCSI
device in the server. (See your server documentation or the system label inside the
server cover for the location of the SCSI connector on the backplane.)
12.
If you have physical drives to install, install them now. See your server
documentation for drive installation instructions.
Note:
The ServeRAID controllers use SCSI ID 7 and/or 6.
13.
Install the server cover.
14.
If you disconnected the cables and power cords in step 2 on page 146, reconnect
the cables and cords. See your server documentation if you need detailed
instructions.
Figure 5. Connecting a ServeRAID-4H controller internal
channel connector