IBM 86655RY Hardware Maintenance Manual - Page 28
ServeRAID ISPR, BCS, and ECS POST error, codes, Basic Configuration Status Register code
![]() |
View all IBM 86655RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Recoverable configuration error. Explanation: The configuration data stored in NVRAM does not match the configuration data stored in the EEPROM. Action: 1. Press Ctrl+I to access the ServeRAID Mini-Configuration menu. 2. Select Advanced Functions from the Main Menu. 3. Select Copy the Configuration from Drives to the Controller. Unrecoverable configuration error. Explanation: The configuration data stored in NVRAM does not match the configuration data stored in the EEPROM. Action: 1. Press Ctrl+I to access the ServeRAID Mini-Configuration menu. 2. Select Advanced Functions from the Main Menu. 3. Select Restore to the Factory Default Settings. WARNING: n logical drives are critical; n logical drives are offline. Explanation: One or more physical drives have failed. Action: Replace the defunct drives as soon as possible to prevent data loss. Your server has an error due to a Blocked Logical Drive. Explanation: One or more logical drives are blocked. A blocked logical drive cannot be accessed. Action: Press F4 to unblock the logical drive, or press F5 to continue without unblocking. ServeRAID ISPR, BCS, and ECS POST error codes After the ServeRAID POST completes, register information appears on the screen in hexadecimal format, as follows: Hardware: ISPR=aaaa BCS=bb ECS=cc ISPR displays the four-digit Interrupt Status Report Register code, BCS displays the Basic Configuration Status Register code, and ECS displays the Extended Configuration Status Register code. 18 Hardware Maintenance Manual: Netfinity 7600 - Type 8665 Models 1RY, 2RY
![](/manual_guide/products/ibm-866561y-hardware-maintenance-manual-c694d19/28.png)