IBM 86655RY Hardware Maintenance Manual - Page 233
DIMM Location J1-J16, Error Code/Symptom
View all IBM 86655RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 233 highlights
Error Code/Symptom FRU/Action 201-XXX-0NN (Failed Memory test, see "Memory Settings" on page 47.) NN = DIMM location. 1. DIMM Location J1-J16 2. Memory card 201-XXX-999 (Multiple DIMM failure, see error text.) 1. See error text for failing DIMMs 2. Memory card 202-XXX-001 Cache test) (Failed System 1. VRM 1 2. Microprocessor CPU 1 202-XXX-002 test) (Failed System Cache 1. VRM 2 2. Microprocessor CPU 2 202-XXX-003 Cache test) (Failed System 1. VRM 3 2. Microprocessor CPU 3 202-XXX-004 Cache test) (Failed System 1. VRM 4 2. Microprocessor CPU 4 206-XXX-000 test) (Failed Diskette Drive 1. Cable 2. Diskette Drive 3. I/O Legacy Board 215-XXX-000 test) (Failed IDE CD-ROM 1. CD-ROM Drive Cables 2. CD-ROM Drive 3. I/O Legacy Board 217-XXX-000 Disk test) (Failed BIOS Fixed 1. Fixed Disk 1 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-001 (Failed BIOS Fixed Disk 1. Fixed Disk 2 test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-002 (Failed BIOS Fixed Disk 1. Fixed Disk 3 test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-003 (Failed BIOS Fixed Disk 1. Fixed Disk 4 test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-004 (Failed BIOS Fixed Disk 1. Fixed Disk 5 test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. Symptom-to-FRU index 223