IBM 86655RY Hardware Maintenance Manual - Page 246
SCSI error codes, Temperature error messages, Power Supply X Temperature Fault
![]() |
View all IBM 86655RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 246 highlights
Error Code/Symptom Bxxx (SCSI bus interface error) SCSI error codes Action 1. Refer to "ServeRAID POST (ISPR) error procedures" on page 232. 2. SCSI cable 3. SCSI backplane 4. Hard drive 5. ServeRAID 3HB Adapter/Controller Error Code All SCSI Errors One or more of the following might be causing the problem: • A failing SCSI device (adapter, drive, controller) • An improper SCSI configuration or SCSI termination jumper setting • Duplicate SCSI IDs in the same SCSI chain • A missing or improperly installed SCSI terminator • A defective SCSI terminator • An improperly installed cable • A defective cable FRU/Action 1. External SCSI devices must be powered-on before you power-on the server. 2. The cables for all external SCSI devices are connected correctly. 3. If you have attached an external SCSI device to the server, make sure the external SCSI termination is set to automatic. 4. The last device in each SCSI chain is terminated correctly. 5. The SCSI devices are configured correctly. Temperature error messages Message DASD "X" Over Temperature (level-critical; Direct Access Storage Device bay "X" was over temperature) DASD Over recommended Temperature (sensor X) (level-warning; the DASD backplane had an over temperature condition) DASD under recommended temperature (sensor X) level-warning; the DASD backplane had an under temperature condition) Power Supply "X" Temperature Fault (level-critical; power supply "x" had over temperature condition) System board is over recommended temperature (level-warning; system board is over recommended temperature) System board is under recommended temperature (level-warning; system board is under recommended temperature) Action 1. Ensure system is being properly cooled; see "Temperature checkout" on page 31. 1. Ensure system is being properly cooled; see "Temperature checkout" on page 31. 1. Ambient temperature must be within normal operating specifications; (see "Features and specifications" on page 3). 1. Ensure system is being properly cooled; see "Temperature checkout" on page 31. 2. Replace Power Supply "X" 1. Ensure system is being properly cooled; see "Temperature checkout" on page 31. 2. Replace system board 1. Ambient temperature must be within normal operating specifications; (see "Features and specifications" on page 3). 236 Hardware Maintenance Manual: Netfinity 7600 - Type 8665 Models 1RY, 2RY
![](/manual_guide/products/ibm-866561y-hardware-maintenance-manual-c694d19/246.png)