IBM 86655RY Hardware Maintenance Manual - Page 232
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S., VRM for Optional Microprocessor 3
![]() |
View all IBM 86655RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 232 highlights
Error Code/Symptom FRU/Action 035-XXX-SNN (Check System Error 1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S. Log before replacing a FRU. S = number of failing PCI slot; NN = SCSI ID of failing fixed disk.) 035-253-S99 (RAID adapter initialization failure) 1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. SCSI Backplane 4. Adapter 075-XXX-000 test) (Failed Power Supply 1. Power Supply 089-XXX-001 test) (Failed Microprocessor 1. VRM for Microprocessor 1 2. Microprocessor 089-XXX-002 (Failed Optional Microprocessor test) 1. VRM for Optional Microprocessor 2 2. Optional Microprocessor 089-XXX-003 (Failed Optional Microprocessor test) 1. VRM for Optional Microprocessor 3 2. Optional Microprocessor 089-XXX-004 (Failed Optional Microprocessor test) 1. VRM for Optional Microprocessor 4 2. Optional Microprocessor 165-XXX-000 (Failed Service Processor test) 1. Check error log for any I2C messages (see "I2C bus fault messages" on page 239). 2. Remove ac power from system for 20 seconds, then rerun service processor test. If problem persists, proceed to step 3.. 3. I/O Legacy Board. Before replacing the I/O Legacy Board, ensure that I/O Legacy Board jumper J28 is not installed (the default) when the error occurs. 180-XXX-000 (Diagnostics LED failure) 1. Run Diagnostic LED test for the failing LED. 180-XXX-001 (Failed information LED 1. Information LED Panel panel test) 2. Diagnostic LED Panel 3. I/O Legacy Board 180-XXX-002 Panel test) (Failed Diagnostics LED 1. Diagnostics LED Panel 2. I/O Legacy Board 180-XXX-003 LED test) (Failed System Board 1. System Board 180-XXX-004 Board LED test) (Failed Processor 1. Processor/PCI Board 2. I/O Legacy Board 180-XXX-005 (Failed SCSI Backplane LED test) 1. SCSI Backplane 2. SCSI Backplane Cable 3. I/O Legacy Board 180-XXX-006 (Memory Board LED test) 1. Memory Board 2. Processor/PCI Board 3. I/O Legacy Board 222 Hardware Maintenance Manual: Netfinity 7600 - Type 8665 Models 1RY, 2RY
![](/manual_guide/products/ibm-866561y-hardware-maintenance-manual-c694d19/232.png)