Error Code/Symptom FRU/Action 201 (Memory test error, see "Memory 1. Run memory diagnostics. Settings" on page 47.) If the server does not have the latest level of BIOS installed, 2. DIMM update the BIOS to the latest level and run 3. Memory card the diagnostic program again. 4. Processor/PCI Board 5. I/O Legacy Board 229 (Cache error) 1. Processor 2. Optional Processor (if installed) 3. Processor/PCI Board 289 (DIMM has been disabled by user 1. Run Configuration/Setup, if disabled by user or system, see "Memory Settings" on page 47.) 2. Disabled DIMM, if not disabled by user. 3. Processor/PCI Board 301 (Keyboard or keyboard controller error) 1. Keyboard 2. I/O Legacy Board 303 (Keyboard controller error) 1. I/O Legacy Board 2. Keyboard 602 (Invalid diskette boot record) 1. Diskette 2. Diskette Drive 3. Cable 4. I/O Legacy Board 604 (Diskette drive error) 1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. I/O Legacy Board 605 (Unlock error) 1. Diskette drive 2. Drive cable 3. I/O Legacy board 662 (Diskette drive configuration error) 1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. I/O Legacy Board 762 (Coprocessor configuration error) 1. Run Configuration/Setup utility 2. Battery 3. Processor 4. Processor/PCI board 962 (Parallel port error) 1. Disconnect external cable on parallel port. 2. Run Configuration/Setup 3. I/O Legacy Board 11XX (System board serial port 1 or 2 error) 1. Disconnect external cable on serial port. 2. Run Configuration/Setup 3. I/O Legacy Board 228 Hardware Maintenance Manual: Netfinity 7600 - Type 8665 Models 1RY, 2RY
![](/manual_guide/products/ibm-866561y-hardware-maintenance-manual-c694d19/238.png)