IBM 86655RY Hardware Maintenance Manual - Page 182
startdely, ipssend startdely, channel, controller options, controller, options
![]() |
View all IBM 86655RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 182 highlights
startdely Note: channel represents the drive channel (1, 2, 3, or 4), and sid is the SCSI ID for the device (0-15). Use the startdely function to set the number of drives in a group to start up simultaneously and to set the delay in seconds between the startup of these groups of drives. Supported operating systems: DOS Command: ipssend startdely controller options where: • controller is the ServeRAID controller number (1-12) • options is one of the following: - ? displays the concurrent drive startup count and the delay time. - A number (1-16) that specifies the new concurrent drive startup count. - A number (1-16) that specifies the new concurrent drive startup count and a number (3-15) that specifies the startup delay time, in seconds. 172 Hardware Maintenance Manual: Netfinity 7600 - Type 8665 Models 1RY, 2RY
![](/manual_guide/products/ibm-866561y-hardware-maintenance-manual-c694d19/182.png)