IBM 86655RY Hardware Maintenance Manual - Page 237
Run Configuration/Setup
![]() |
View all IBM 86655RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 237 highlights
Error Code/Symptom FRU/Action 114 (Adapter read-only memory error) 1. Failing adapter 2. Run diagnostics 129 (Internal cache error) 1. Processor 2. Optional processor (if installed) 3. Processor/PCI board 151 (Real time clock error) 1. Run Diagnostics 2. Battery 3. I/O Legacy Board 161 (Real time clock battery error) 1. Run Configuration/Setup 2. Battery 3. I/O Legacy Board 162 (Device Configuration Error) 1. Run Configuration/Setup Note: Be sure to load the default settings 2. Battery and any additional desired settings; then, save the configura- 3. Failing Device tion. 4. I/O Legacy Board 163 (Real-Time Clock error) 1. Run Configuration/Setup 2. Battery 3. I/O Legacy Board 164 (Memory configuration changed, see 1. Run Configuration/Setup "Memory Settings" on page 47.) 2. DIMM 3. Processor/PCI Board 175 (Hardware error) 1. I/O Legacy Board 2. Processor/PCI Board 176(Computer cover or cable cover was removed without a key being used) 1. Run Configuration/Setup 2. I/O Legacy Board 3. C2 Security Switch 177, 178 (Security hardware error) 1. Run Configuration/Setup 2. I/O Legacy Board 184 (Power-on password corrupted) 1. Run Configuration/Setup 2. I/O Legacy Board 185 (Drive startup sequence information corrupted) 1. Run Configuration/Setup 2. I/O Legacy Board 186 (Security hardware control logic failed) 1. Run Configuration/Setup 2. I/O Legacy Board 187 (VPD serial number not set.) 1. Set serial number in Setup 2. I/O Legacy Board 188 (Bad EEPROM CRC #2) 1. Run Configuration/Setup 2. I/O Legacy Board 189 (An attempt was made to 1. Run Configuration/Setup, enter the administrator password access the server with invalid passwords) 2. I/O Legacy Board. Symptom-to-FRU index 227
![](/manual_guide/products/ibm-866561y-hardware-maintenance-manual-c694d19/237.png)