Icom IC-92AD Instruction Manual - Page 107
DPTT lock DBusy lockout DTime-out timer DActive band DDial replace
![]() |
View all Icom IC-92AD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
MENU SCREEN OPERATION 12 D PTT lock Turns the PTT lock function ON and OFF. Transmission with [PTT] is inhibited when ON is selected to prevent accidental transmission, etc. (default: OFF) PTT LOCK rOFF ON PTT LOCK OFF rON D Busy lockout Turns the busy lockout function ON and OFF. This function inhibits transmission while receiving a signal or when the squelch is open. (default: OFF) BUSY LOCKOUT rOFF ON BUSY LOCKOUT OFF rON D Time-out timer To prevent accidental prolonged transmission, etc., the transceiver has a time-out timer. This function cuts transmis- sion OFF after 1, 3, 5 or 10 min. of continuous transmission. This timer can be cancelled. • OFF : The time-out timer is turned OFF. (default) • 1 to 10 MIN : The transmission is cut OFF after the set period elapses. TIME-OUT TIMER TIME-OUT TIMER 1 rOFF OFF 1MIN 1MIN 2 3MIN 3MIN 5MIN 5MIN 3 10MIN r10MIN 4 D Active band 5 Allows continuous frequency selection of the operating fre- 6 quency across all bands. • SINGLE : A single operating frequency can be 7 • ALL selected within the current band. Push 8 [BAND] for band selection in this case. : The operating frequency can be selected 9 continuously. (default) 10 ACTIVE BAND ACTIVE BAND SINGLE rALL rSINGLE ALL 11 12 D Dial replace 13 Exchanging [DIAL] and [VOL] function. 14 • OFF • ON : The dial replace function is turned OFF. 15 (default) : The dial replace function is turned ON. 16 DIAL REPLACE rOFF ON DIAL REPLACE OFF rON 17 18 19 99
![](/manual_guide/products/icom-ic92ad-instruction-manual-b1b3608/107.png)