10 SCAN OPERATION ■ Scan edges programming Scan edges can be programmed in the same manner as memory channels. Scan edges are programmed into scan edges, 00A/00B to 24A/24B, in memory channels. q Push [VFO] to select VFO mode. w Set the desired frequency: ➥ Select the desired band with [BAND]. ➥ Set the desired frequency with [DIAL]. ➥ Program different frequencies in "✱✱A" and "✱✱B" re- spectively. ➥ Set other data (e.g. offset frequency, duplex direction, tone squelch, etc.), if desired. e Push and hold [S.MW](MR) for 1 sec. to enter the select memory write mode. • 1 short and 1 long beeps sound. • Memory channel number blinks. r Rotate [DIAL] to select the desired programmed scan edge channel from 00A to 24A. t Push and hold [S.MW](MR) for 1 sec. • 3 beeps sound. • The other scan edge channel "B," 00B to 24B, is automatically selected when continuing to push [S.MW](MR) after programming. y To program a frequency for the other pair of scan edges, 00B to 24B, repeat steps w and r. • If the same frequency is programmed into a pair of scan edges, programmed scan will not function. [DIAL] D BAND VFOA MHz MR B S.MW [EXAMPLE]: Programming 145.300 MHz into scan edges 03A. Push and hold MR B S.MW for 1 sec. Rotate [DIAL]. Push and hold MR B S.MW for 1 sec. FM A145 300 PSKIP FM r146 010 µ 001 BANK :---- MNAME: SKIP :OFF FM r µ 03A BANK :---- MNAME: SNAME: FM A145 300 PSKIP 03A FM A145 300 PSKIP 84