12 MENU SCREEN OPERATION ■ DUP/TONE set mode items D Offset frequency Sets the offset frequency for duplex (repeater) operation within a 0 to 159.995 MHz range. OFFSET FREQ 0.000.00 OFFSET FREQ 159.995.00 The default value may differ according to the selected frequency band (before accessing DUP/TONE set mode) and transceiver version. The selected tuning step in VFO mode is used when setting the offset frequency. D Repeater tone frequency Selects subaudible tone frequency for accessing a repeater, etc. 50 tone frequencies (67.0-254.1 Hz) are available. (default: 88.5) REPEATER TONE 88.5 REPEATER TONE 254.1 D TSQL frequency Selects tone frequency for tone squelch or pocket beep operation from one of 50 available frequencies (67.0-254.1 Hz). (default: 88.5) CTCSS TONE 88.5 CTCSS TONE 254.1 • Available subaudible tone frequencies 67.0 79.7 94.8 110.9 131.8 156.7 171.3 186.2 203.5 229.1 69.3 82.5 97.4 114.8 136.5 159.8 173.8 189.9 206.5 233.6 71.9 85.4 100.0 118.8 141.3 162.2 177.3 192.8 210.7 241.8 74.4 88.5 103.5 123.0 146.2 165.5 179.9 196.6 218.1 250.3 77.0 91.5 107.2 127.3 151.4 167.9 183.5 199.5 225.7 254.1 The transceiver has 50 tone frequencies and consequently their spacing is narrow compared with units having 38 tones. Therefore, some tone frequencies may receive interference from adjacent tone frequencies. 110