HD Integrated Camera 3.1.1. Power On/Standby Interface Specifications These commands enable the power On/Standby of the camera to be controlled and the current power On/Standby statuses to be acquired. Command name Power On/ Standby control command Power On/ Standby query command Category Control Response Request Response Table 3.1.1. Power On/Standby Command Data value Setting #O[Data] 0 f Standby Standby 1 Power On n Power On p[Data] #O None p[Data] 0 1 Standby Power On 3 Transferring from Standby to ON Remarks ※ Not supported by the AK-UB300. ※ Not supported by the AK-UB300. Example of use) Power: On [Control] PC → AW-HE50 http://192.168.0.10/cgi-bin/aw_ptz?cmd=%23O1&res=1 [Response] AW-HE50 → PC 200 OK "p1" © Panasonic Corporation 2020 All Rights Reserved. - 11 -