Panasonic AW-HE42 IP Control Specifications - Page 42
OAF:1, OAF:1, OAF:0, OAF:0
![]() |
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
HD Integrated Camera The following restrictions should be noted when using these commands. These restrictions are as follows. Interface Specifications 【Restrictions】 1. When sending the camera control commands, send the commands with a gap of 130 ms between each command. Given below is the command sequence. PC1 (Client) ① http://192.168.0.10/cgi-bin/aw_cam?cmd= OAF:1 &res=1 200 OK "OAF:1" When sending the commands, leave a gap of at least 130 ms between each command. ② http://192.168.0.10/cgi-bin/aw_cam?cmd= OAF:0 &res=1 200 OK "OAF:0" Camera Fig.3.2-2 Restrictions 2. Send the commands which change the settings only at the point in time when the changes are required. (Do not send them at regular intervals.) ※The applicable models incorporate an EEPROM for storing the settings, and each time a command that changes the settings is received, data is written in the EEPROM. The number of times data can be written in the EEPROM is limited so if data is sent frequently, the model will cease to operate normally when the maximum number of times for writing the data has been reached. © Panasonic Corporation 2020 All Rights Reserved. - 42 -