OSJ:48:[Data], OSJ:49:[Data], AWB COLOR, TEMPERATURE, OSJ:4A:[Data, Valid, Under, QSJ:4A
![]() |
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 122 highlights
HD Integrated Camera Command name Category Command AWB gain offset query command Request QSJ:0C Response OSJ:0C:[Data] ATW Target R control command Control OSJ:0D:[Data] Response OSJ:0D:[Data] Data value None 0h 1h 76h Setting Off On -10 80h 0 ~ ~ ~ ~ ATW Target R query command Request QSJ:0D Response OSJ:0D:[Data] 8Ah +10 None 76h -10 ~ ~ ~ ~ 80h 0 8Ah +10 ATW Target B Control OSJ:0E:[Data] 76h -10 control command Response OSJ:0E:[Data] 80h 0 ~ ~ ~ ~ ATW Target B query command Request QSJ:0E Response OSJ:0E:[Data] 8Ah +10 None 76h -10 ~ ~ ~ ~ 80h 0 AWB COLOR TEMPERATURE INC control command AWB COLOR TEMPERATURE DEC control command AWB COLOR TEMPERATURE query command Control Response Control Response Control Response OSJ:48:[Data] OSJ:48:[Data] OSJ:49:[Data] OSJ:49:[Data] OSJ:4A:[Data 1]:[Data2] OSJ:4A:[Data 1]:[Data2] ~ ~ 8Ah 1h Ah 1h Ah [Data 1] 007D 0h ~ ~ +10 1 10 1 10 2000 K 15000 K ~ ~ Request Response QSJ:4A OSJ:4A:[Data 1]:[Data2] 03A9 8h [Data 2] 0h 1h 2h None [Data 1] 007D 0h Valid Under Over 2000 K 15000 K ~ ~ 03A9 8h [Data 2] Interface Specifications Remarks ※Only supported by the AW-UE150 ※Only supported by the AW-UE150 ※Only supported by the AW-UE150 ※Only supported by the AW-UE150 ※Only supported by the AW-UE150 ・[Data2] is fixed at 0 © Panasonic Corporation 2020 All Rights Reserved. - 122 -
![](/manual_guide/products/panasonic-awhe42-ip-control-specifications-f4b7fd2/122.png)