Panasonic AW-HE42 IP Control Specifications - Page 31
Command name, Category, Command, value, Setting, Remarks
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
HD Integrated Camera Command name Category Command Interface Specifications Data value Setting Remarks 25h CAMERA communication Error 26h CAMERA RX Over run Error 27h CAMERA RX Framing Error 28h CAMERA RX Command Buffer Overflow In the case of the AW-HR140 00h Disable Normal 01h Enable - 02h - 03h Motor Driver Error 04h Pan Sensor Error 05h Tilt Sensor Error 06h Controller RX Over run Error 07h Controller RX Framing Error 08h Network RX Over run Error 09h Network RX Framing Error 0Ah - 0Bh - - - 17h Controller RX Command Buffer Overflow - - 19h Network RX Command Buffer Overflow - - 21h System Error 22h Spec Limit Over - - 24h Network communication Error 25h CAMERA communication Error 26h CAMERA RX Over run Error 27h CAMERA RX Framing Error 28h CAMERA RX Command Buffer Overflow - - 31h Fan1 error 32h Fan2 error 33h High Temp - - 36h Low Temp - - 39h Wiper Error 40h Temp Sensor Error - - 50h MR Level Error 51h GYRO Initial Error 52h MR Offset Error 53h Origin Offset Error In the case of the AW-HE40/AW-UE70/AW-HE42 00h Disable Normal(No Error) 03h Enable Motor Driver Error 04h Pan Sensor Error 05h Tilt Sensor Error 06h IF/FPGA UART Over run Error 07h IF/FPGA UART Framing Error 08h IF/NET UART Over run Error © Panasonic Corporation 2020 All Rights Reserved. - 31 -