Panasonic AW-HE42 IP Control Specifications - Page 41
OAF:1, OAF:1
![]() |
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
HD Integrated Camera Interface Specifications Given below is the sequence used when communication has been performed in accordance with the command format described on the previous page. For the sequence when errors have been generated in response to commands, refer to "6. Error return". 【Sequence】 "PC1" is the control terminal in the sequence below. Example: Focus setting = Auto Camera IP Address = 192.168.0.10 Command = OAF:1 Auto focus control is performed from PC1, and [200 OK "OAF:1"] is returned as the response. Both a control command and query command are available as the camera control commands. Given below is the command sequence. PC1 (Client) Camera http://192.168.0.10/cgi-bin/aw_cam?cmd= OAF:1 &res=1 200 OK "OAF:1" Auto focus established as the setting Fig.3.2-1 Camera control command sequence © Panasonic Corporation 2020 All Rights Reserved. - 41 -
![](/manual_guide/products/panasonic-awhe42-ip-control-specifications-f4b7fd2/41.png)