HD Integrated Camera 3.2.39. Intelligent Interface Specifications These commands configure the Intelligent settings and acquire the current setting values. Command name Intelligent control command Intelligent query command Intelligent Mode control command Intelligent Mode query command Intelligent ND Filter control command Intelligent ND Filter query command Intelligent AGC Mode control command Intelligent AGC Mode query command Category Control Response Request Response Control Response Request Response Control Response Request Response Control Response Request Response Table 3.2.39. Intelligent Command Data value Setting OSI:21:[Data] 0 1 OSI:21:[Data] 2 Off On Lock QSI:21 None OSI:21:[Data] 0 Off 1 On 2 Lock OSI:22:[Data] 0 1 OSI:22:[Data] AE AE+ATW QSI:22 None OSI:22:[Data] 0 1 AE AE+ATW OSI:23:[Data] 0 Through 1 OSI:23:[Data] 2 3 1/8 1/64 Auto QSI:23 None OSI:23:[Data] 0 1 2 Through 1/8 1/64 3 Auto OSI:24:[Data] 0 1 OSI:24:[Data] 2 Normal Sports SN QSI:24 None OSI:24:[Data] 0 1 Normal Sports 2 SN Remarks ※ Only supported by the AW-HR140. ※ Only supported by the AW-HR140. ※ Only supported by the AW-HR140. ※ Only supported by the AW-HR140. Example of use) ・Intelligent settings: On [Control] PC → AW-HR140 http://192.168.0.10/cgi-bin/aw_cam?cmd=OSI:21:1&res=1 [Response] AW-HR140 → PC 200 OK "OSI:21:1" © Panasonic Corporation 2020 All Rights Reserved. - 201 -