Panasonic AW-HE42 IP Control Specifications - Page 138
Panasonic Corporation 2020 All Rights Reserved., Example of use, Pedestal, AW-HE50, Pedestal: +10
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
HD Integrated Camera Interface Specifications Command name Pedestal query command Pedestal control command Category Command Data value Setting Remarks Request QTD Response OTD:[Data] None In the case of the AW-HE50/AW-HE60/AW-HE40/ AW-UE70/AW-HE42 00h -10 Data value of response = (Setting x 3 + 0x1E) 1Eh 0 ~ ~ ~ ~ 3Ch +10 In the case of the AW-HE120/AW-HE130/AW-HR140 00h -150 Data value of response = (Setting / 5 + 0x1E) 1Eh 0 ~ ~ ~ ~ Control 3Ch OSG:4A:[Data] 1Dh +150 -99 ※Only enabled for the AK-UB300. 80h 0 ~ ~ ~ ~ Response OSG:4A:[Data] E3h +99 Pedestal Request QSG:4A None ※Only enabled for the AK-UB300. query command Response OSG:4A:[Data] 1Dh -99 ~ ~ ~ ~ 80h 0 E3h +99 Example of use) ・Pedestal: -10 [Control] PC → AW-HE50 http://192.168.0.10/cgi-bin/aw_cam?cmd=OTP:000&res=1 [Response] AW-HE50 → PC 200 OK "OTP:000" ・Pedestal: +10 [Control] PC → AW-HE50 http://192.168.0.10/cgi-bin/aw_cam?cmd=OTD:3C&res=1 [Response] AW-HE50 → PC 200 OK "OTD:3C" © Panasonic Corporation 2020 All Rights Reserved. - 138 -