Panasonic AW-HE42 IP Control Specifications - Page 22
Command name, Category, Command, Data value, Setting, Remarks
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
HD Integrated Camera Interface Specifications Command name Freeze during preset control command Freeze during preset query command Preset Speed Table control command Preset Speed Table query command Preset Entry query command Category Control Response Request Response Control Response Request Response Request Response Command #PRF[Data] pRF[Data] #PRF pRF[Data] #PST[Data] pST[Data] #PST pST[Data] #PE[Data1] pE[Data1][D ata2] Data value Setting Remarks 999 30 : Fast Preset Speed Unit: Time 001 1sec ~ ~ 063 99sec 0 OFF ※Only supported by the 1 ON AW-HE130/AW-HE40/AW-U 0 OFF 1 ON None E70/AW-HE42/AW-HR140/A W-UE150. ※Only supported by the 0 OFF 1 ON AW-HE130/AW-HE40/AW-U E70/AW-HE42/AW-HR140/A W-UE150. In the case of the AW-HE40/AW-UE70/AW-HE42 0 SLOW 1 MID 2 HIGH In the case of the AW-HE130/AW-HR140/AW-UE150 0 SLOW 2 HIGH None In the case of the AW-HE40/AW-UE70/AW-HE42 0 SLOW 1 MID 2 HIGH In the case of the AW-HE130/AW-HR140/AW-UE150 0 SLOW 2 HIGH [Data1] 00h 01h 02h [Data1] 00h 01h 02h [Data1] Preset 001~040 Preset 041~080 Preset 081~100 [Data1] Preset 001~040 Preset 041~080 Preset 081~100 ※Max 100Preset [Data2] 00000000 00h FFFFFFF FFFh (bit0) 0 1 (bit1) 0 1 (39bit) 0 1 [Data2] PRESET No.(Data1*40 + 1) No Entry Entry PRESET No.(Data1*40 + 2) No Entry Entry PRESET No.(Data1*40 + 40) No Entry Entry © Panasonic Corporation 2020 All Rights Reserved. - 22 -