Panasonic AW-HE42 IP Control Specifications - Page 260
h Controller RX Command Buffer Overflow
![]() |
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 260 highlights
HD Integrated Camera Notification Error Code In the case of the AW-UE150 00h Normal 03h Motor Driver Error 04h Pan Sensor Error 05h Tilt Sensor Error 06h Controller RX Over run Error 07h Controller RX Framing Error 08h Network RX Over run Error 09h Network RX Framing Error 17h Controller RX Command Buffer Overflow 19h Network RX Command Buffer Overflow 21h System Error 22h Spec Limit Over 23h FPGA Config Error 24h NET Life-monitoring Error 25h BE Life-monitoring Error 26h IF/BE UART Buffer Overflow 27h IF/BE UART Framing Error 28h IF/BE UART Buffer Overflow 29h CAM Life-monitoring Error 31h Fan1 error 32h Fan2 error 33h High Temp 36h Low Temp 40h Temp Sensor Error 41h Lens Initialize Error 42h PT. Initialize Error 50h MR Level Error 52h MR Offset Error 53h Origin Offset Error 54h Angle MR Sensor Error 55h PT. Gear Error 56h Motor Disconnect Error Interface Specifications © Panasonic Corporation 2020 All Rights Reserved. - 260 -