HD Integrated Camera Interface Specifications 4.3. Setting change sequence Update notifications are sent when the settings or statuses of the camera have been changed. Given below is an example of the update notification sequence. It is assumed that the update notification start command has been sent to all the terminals in the sequence and that the terminals can receive the update notifications from the camera. 4.3.1. Changing the settings from a terminal 【Changing the settings from the local terminal】 When the settings of the camera have been changed from the local terminal (PC1), the changes are also posted by an update notification separately from the HTTP response to the command. PC1 (Client) Camera http://192.168.0.10/cgi-bin/aw_cam?cmd= OGU:08 &res=1 200 OK "OGU:08" [CR][LF] OGU:08 [CR][LF] Fig.4-4 Changing the settings from the local terminal © Panasonic Corporation 2020 All Rights Reserved. - 216 -