Panasonic AW-HE42 IP Control Specifications - Page 123
Panasonic Corporation 2020 All Rights Reserved., Example of use, AWB AWC execution, AW-HE50, AWB AWC
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 123 highlights
HD Integrated Camera Command name AWB R Gain control command Category Control Response Command OSJ:4B:[Data] OSJ:4B:[Data] Data value 0h 1h 2h 670h 800h Setting Valid Under Over -400 0 AWB R Gain query command Request Response QSJ:4B OSJ:4B:[Data] 990h None 670h 400 -400 ~ ~ ~ ~ 800h 0 AWB B Gain control command Control Response OSJ:4C:[Data] OSJ:4C:[Data] 990h 670h 800h 400 -400 0 ~ ~ ~ ~ AWB B Gain query command Request Response QSJ:4C OSJ:4C:[Data] 990h None 670h 400 -400 ~ ~ ~ ~ 800h 0 AWB G Axis control command Control Response OSJ:4D:[Data] OSJ:4D:[Data] 990h 670h 800h 400 -400 0 ~ ~ ~ ~ AWB G Axis query command Request Response QSJ:4D OSJ:4D:[Data] 990h None 670h 400 -400 800h 0 990h 400 Interface Specifications Remarks ※Only supported by the AW-UE150 ※Only supported by the AW-UE150 ※Only supported by the AW-UE150 Example of use) ・AWB (AWC) execution [Control] PC → AW-HE50 http://192.168.0.10/cgi-bin/aw_cam?cmd=OWS&res=0 [Response] AW-HE50 → PC None ・AWB (AWC), ABB execution underway status display: On [Control] PC → AW-HE50 http://192.168.0.10/cgi-bin/aw_cam?cmd=OSA:88:1&res=1 [Response] AW-HE50 → PC 200 OK "OSA:88:1" © Panasonic Corporation 2020 All Rights Reserved. - 123 -