Panasonic AW-HE42 IP Control Specifications - Page 173
Frequency setting
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 173 highlights
HD Integrated Camera 3.2.25. Frequency setting Interface Specifications These commands enable the system frequency to be switched and the current setting to be acquired. Command name Frequency control command Frequency query command Category Control Response Request Response Table 3.2.25. Frequency Command Data value Setting Remarks OSE:77:[Data] In the case of the AW-HE50/AW-HE60/AW-HE40/AW-UE70/AW-HE42AW-HE120 /AW-HE130/AW-HR140 0 59.94Hz 1 50Hz ※The AW-HE50 is supported by Ver.2 or a later version. OSE:77:[Data] In the case of the AW-UE150 0 59.94Hz 1 50Hz 2 24Hz 3 23.98Hz QSE:77 None . OSE:77:[Data] In the case of the AW-HE50/AW-HE60/AW-HE40/AW-UE70/AW-HE42AW-HE120 /AW-HE130/AW-HR140 0 59.94Hz ※The AW-HE50 is supported by 1 50Hz Ver.2 or a later version. In the case of the AW-UE150 0 59.94Hz 1 50Hz 2 24Hz 3 23.98Hz Example of use) Frequency: 50Hz [Control] PC → AW-HE120 http://192.168.0.10/cgi-bin/aw_cam?cmd=OSE:77:1&res=1 [Response] AW-HE120 → PC 200 OK "OSE:77:1" © Panasonic Corporation 2020 All Rights Reserved. - 173 -