HD Integrated Camera Camera information ※Only AW-UE150 Preset Name ※Only AW-UE150 Preset Zoom Mode ※Only AW-UE150 Operation Lock Status ※Only AW-UE150 ERROR INFORMATION ※Only AW-UE150 P/T Absolute Position Control ※Only AW-UE150 Power On Position ※Only AW-UE150 Power On Preset Number ※Only AW-UE150 Shooting Mode ※Only AK-UB300/AW-UE150 A.IRIS LEVEL ※Only AK-UB300 LOW GAIN ※Only AK-UB300 MID GAIN ※Only AK-UB300 HIGH GAIN ※Only AK-UB300 MODE @S.GAIN ※Only AK-UB300 MATRIX ※Only AK-UB300 MATRIX TABLE Interface Specifications Command OSJ:2C:0x[data] OSE:7D:[data] OSJ:40:[data1]:[data 2] OSI:46:0x[data] aPC[data1][data2] [data] section 1: On 0: Reset 1: Hold 0: Mode A 1: Mode B [Data1] 0: Unlock 1: Lock [Data2] Any Information (40 Charactors) 00000000h: No Error 00000001h: Fan Error 00000002h: High Temperature 00000004h: Lens Error 00000008h: Pan/Tilt Error 00000010h: Sensor Error [Data1]Pan Position 0000h: CCW Limit ~ 8000h: Center ~ FFFFh: CW Limit OSJ:45:[data] OSJ:46:[data] OSI:30:[data] OSI:1D:0x[data] OSA:50:0x[data] OSA:51:0x[data] OSA:52:0x[data] OSA:60:[data] OSG:A0:[data] OSA:84:[data] [Data2]Tilt Position 0000h: UP Limit ~ 8000h: Center ~ FFFFh: DOWN Limit 0: None 1: Standby 2: Home 3: Preset 00: Preset001 ~ 99: Preset100 0: NORMAL 1: HIGH SENS. 00h: 0 ~ 64h :100 7Ah: -6dB ~ 88h: 36dB 7Ah: -6dB ~ 88h: 36dB 7Ah: -6dB ~ 88h: 36dB 0: S.GAIN1 1: S.GAIN2 2: S.GAIN3 0: Off 1: On 0: Off © Panasonic Corporation 2020 All Rights Reserved. - 290 -