Panasonic AW-HE42 IP Control Specifications - Page 199
Data6] V POS MG
![]() |
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 199 highlights
HD Integrated Camera Interface Specifications Command name CROP H/V POSITION Speed Control (YL/G/MG) Category Control Response Command OSJ:A0:[Data1 ]:[Data2]:[Data 3]:[Data4]:[Dat a5]:[Data6] Data value 438h 5A0h [Data3] 000h 780h A00h [Data4] 000h 438h 5A0h [Data5] 000h 780h A00h [Data6] 000h 438h 5A0h [Data1] 01 50 99 [Data2] 01 50 99 [Data3] 01 50 99 [Data4] 01 50 99 [Data5] 01 50 - Setting 1080 1440 [Data3] H POS (G) 0 1920 2560 [Data4] V POS (G) 0 1080 1440 [Data5] H POS (MG) 0 1920 2560 [Data6] V POS (MG) 0 1080 1440 [Data1] (YL) Left Max. Speed Stop Right Max. Speed [Data2] (YL) Down Max. Speed Stop UP Max. Speed [Data3] (G) Left Max. Speed Stop Right Max. Speed [Data4] (G) Down Max. Speed Stop UP Max. Speed [Data5] (MG) Left Max. Speed Stop - Remarks ※Only supported by the AW-UE150 © Panasonic Corporation 2020 All Rights Reserved. - 199 -
![](/manual_guide/products/panasonic-awhe42-ip-control-specifications-f4b7fd2/199.png)