HD Integrated Camera 3.1.8. Tally Interface Specifications These commands exercise enable/disable control over the tally input of the camera and enable the current tally input enable/disable statuses to be acquired. In addition, they exercise tally On/Off control over the camera. Command name Tally input enable/disable control command Tally input enable/disable query command R-Tally On/Off control command R-Tally On/Off query command Tally Information query command Category Command Control #TAE[Data] Response tAE[Data] Request #TAE Response tAE[Data] Control #DA[Data] Response dA[Data] Request #DA Response dA[Data] Request Response #TAA tAA[Data1] [Data2] [Data3] [Data4] [Data5] [Data6] [Data7] [Data8] [Data9] Table 3.1.8. Tally Data value Setting 0 Disable 1 Enable Remarks ※ Not supported by the AK-UB300/AW-HR140. None 0 1 0 1 Disable Enable R-Tally Off R-Tally On ※Effective for R-Tally, G-Tally ※ Not supported by the AK-UB300/AW-HR140. ※ Not supported by the AK-UB300. None 0 1 None 0(Off) 1(On) R-Tally Off R-Tally On [Data1] R-Tally On/Off [Data2] Wired R-Tally In On/Off [Data3] Command R-Tally In On/Off [Data4] G-Tally On/Off [Data5] Reserved [Data6] Command G-Tally In On/Off [Data7] Reserved [Data8] Reserved [Data9] Reserved ※ Not supported by the AK-UB300. ※Only supported by the AW-UE150 Example of use) ・Tally input (enable/disable): Enable [Control] PC → AW-HE50 http://192.168.0.10/cgi-bin/aw_ptz?cmd=%23TAE1&res=1 © Panasonic Corporation 2020 All Rights Reserved. - 24 -