HD Integrated Camera Interface Specifications 3.2.6. Gain setting These commands enable the gain settings of the camera to be established and the current settings to be acquired. Command name Gain control command Category Control Table 3.2.6. Gain setting Command Data value Setting Remarks OGU:[Data] In the case of the AW-HE50/AW-HE60 08h 0dB Disabled at the FullAuto setting 0Bh 3dB (ER3 is returned). 0Eh 6dB 11h 9dB 14h 12dB 17h 15dB 1Ah 18dB 80h Auto In the case of the AW-HE120 08h 0dB Value can be set in increments of 1dB. 11h 9dB ~ ~ ~ ~ 1Ah 18dB 80h Auto In the case of the AW-HE130 08h 0db 11h 9db Value can be set in increments of 1dB. ~ ~ ~ ~ ~ ~ 1Ah 18db 2Ch 36db 80h Auto In the case of the AW-HR140/AW-UE150 08h 0db 11h 9db Value can be set in increments of 1dB. 1Ah 18db 2Ch 36db Gain query command Response Request Response OGU:[Data] QGU OGU:[Data] 32h 42db 80h Auto In the case of the AW-HE40/AW-UE70/AW-HE42 08h 0dB 0Bh 3dB Disabled at the FullAuto setting (ER3 is returned). 0Eh 6dB ~ ~ 38h 48dB 80h Auto Value can be set in increments of 3dB. None In the case of the AW-HE50/AW-HE60 08h 0dB 0Bh 3dB 0Eh 6dB 11h 9dB 14h 12dB 17h 15dB 1Ah 18dB © Panasonic Corporation 2020 All Rights Reserved. - 68 -